Prescolite SIGNOS Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Beleuchtung Prescolite SIGNOS herunter. Prescolite SIGNOS User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
InstructionSheet
www.prescolite.com • Prescolite TollFree Technical Support 1.888.PRS.4TEC • Hours: 8am - 5pm ET
101 Corporate Drive • Spartanburg, SC 29303
With representatives of
fices in principal cities throughout North
America.
Copyright 2005, 08/05 revision, All Rights Reserved - Printed in U.S.A.
Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .06600600
InstructionSheet
INSTALLATION INSTRUCTIONS
SIGNOS
1. Remove reflector from fixture and verify that fixture is
secured to ceiling supports so fixture is stable and does
not move. Lower edge of fixture opening (A) should be
situated just above room side surface of ceiling,
approximately 1/8". Adjust fixture position if necessary.
2. Remove skyhook brackets from package. Package
should contain two skyhook “L” bracket’s (B). Verify that
triangular hook bracket (C) with tabs is in the upper-
most position, situated at the top of the slot on both
skyhook brackets. Attach brackets to fixture by hooking
bracket’s lower tab (D) onto slot (E) located on lower
edge of fixture opening (A). Rotate top of bracket over
top edge of fixture opening until bracket’
s upper tabs
(F) snap into holes (G) located on top surface of fixture
flange.
SPECIAL NOTES
Do NOT install decorative trim if parts are
damaged or cracked. • CAUTION: Do NOT
disassemble decorative trim or skyhook
brackets! • Verify that trim flange does NOT
damage ceiling due to interference while
hanging trim down for relamping or rotating
into position during installation.
E
CEILING
SNAP TABS(G)
INT
O HOLES(H)
CEILING
HOOK TAB ON
FLANGE SLOT
ROTATE INTO
POSITION
(CEILING REMOVED FROM VIEW)
A
C
B
F
D
B
G
IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information
and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,
and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and
during servicing or relamping, turn off power at fuse or circuit breaker.
All servicing or relamping must be performed by
qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.
Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in
compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by
the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from
product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or
the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - InstructionSheet

InstructionSheetwww.prescolite.com • Prescolite TollFree Technical Support 1.888.PRS.4TEC • Hours: 8am - 5pm ET101 Corporate Drive • Sparta

Seite 2

www.prescolite.com • Prescolite TollFree Technical Support 1.888.PRS.4TEC • Hours: 8am - 5pm ET101 Corporate Drive • Spartanburg, SC 29303

Kommentare zu diesen Handbüchern

Keine Kommentare